Video of the H&SEs recommended drop test for non fragile roofing carried out on 7.5mm laminated glass

VIDEO: H&SE Drop Test, 7.5mm laminated safety glass fitted into Twinfix Multi-Link Panel

16.07.2012
Video showing the H&SEs recommended drop test, ACR[M]001:2011 carried out on the Twinfix Multi-Link-Panel NF fitted with 7.5 Laminated glass glazing at 600mm centres. It passed the test with a 'B' classication and can therefore be designated as 'non fragile' (NF) or safe.

VIDEO: H&SE Drop Test, 6mm solid polycarbonate glazing fitted into Twinfix Multi-Link-Panel

09.04.2010
Video showing the H&SEs recommended drop test, ACR[M]001:2011 carried out on the Twinfix Multi-Link-Panel NF fitted with 6mm solid polycarbonate glazing at 600mm centres. It passed the test with a 'B' classication and can therefore be designated as 'non fragile' (NF) or safe.

VIDEO: H&SE Drop Test - 6.8mm laminated glass

09.04.2010
This video shows the H&SEs recommended drop test for 'safe' non fragile roofing assemblies carried out on 6.8mm laminated glass fitted into standard glazing bars at 600mm centres. It fails the test, and is therefore designated as 'fragile'. The test, as outlined in ACR[M]001:2011 simulates a person tripping over and falling on a roof.

VIDEO: H&SE Drop Test - 16mm multiwall polycarbonate Multi-Link-Panel Non Fragile

07.01.2010
See the HSE's recommended drop test for assessing 'safe', non-fragile roofing in action. The Twinfix 16mm Multi-Link-Panel NF passes test ACR[M]001:2011 with a 'B' designation.
Video of H&SE Non Fragile drop on 16mm multiwall polycarbonate in standard glazing bars

VIDEO: H&SE Drop Test, standard glazing bar fitted with 16mm Multiwall Polycarbonate

07.01.2010
See the H&SEs recommended drop test for 'safe', non fragile roofing assemblies in action. 16mm multiwall polycarbonate glazing sheet fitted into standard glazing bars at 1000mm centres fails the test. Fitted into the Multi-Link-Panel NF 16mm multiwall passes with a 'B' designation. This demonstrates why 'roofing assemblies' and not individual products have to be tested. It is the patented fixing method in the Multi-Link-Panel NF that holds the multiwall glazing safely in place.